FL Boiling Granulating Drier |
Applications Pharmaceutical industry: tablet, capsule, low sugar or no sugar granule of Chinese medicine Foodstuff: cocoa, coffee, milk powder, juice of granulate, flavoring and so on. Other industries: pesticide, feed, chemical fertilizer, pigment, dyestuff and so on. Pharmaceutical industry: tablet,
Features Because of powder Granulating,the flow property is improved and the dust is reduced; Because of powder Granulating,its solving property is improved; The mixing, Granulating and drying can be completed in one step inside the machine; The operation of equipment is safe because the anti static filtering cloth is adapted; The operation personnel can not be damaged if explosion is taken place because there is releasing hole; The equipment has no dead corner. Therefore the loading and unloading are quick and light and clean. It can meet the requirements of GMP.
Principle The powder grannle the container (fluidization bed) appear the state of fluidization. It is pre-heated and mixed with clean and heated air. At the same time the solution of adhesive solvent is fogged and sprayed into the container. It makes the some particles become granulating that contains adhesive. Being of unceasing dry through hot air, the moisture in the granulating is evaporated and the adhesive is solidification. The process is carried out continuously. Finally it forms ideal, uniform and porous granules.
Technological process 1、Fluid bed unit 2、control flaps 3、Predilter 4、postfilter 5、heater 6、dosing pump 7、Vacuum pump 8、silencer
Flow chart of the content
Technical parameters
Item |
Units |
Models |
3 |
5 |
15 |
30 |
60 |
120 |
200 |
300 |
500 |
Containers of raw materials |
Capacity |
L |
12 |
22 |
45 |
100 |
220 |
420 |
670 |
1000 |
1500 |
Diameter |
mm |
300 |
400 |
550 |
700 |
1000 |
1200 |
1400 |
1600 |
1800 |
Production capacity |
The smallest |
kg |
1.5 |
4 |
10 |
15 |
30 |
80 |
100 |
150 |
250 |
Largest |
kg |
4.5 |
6 |
18 |
36 |
72 |
140 |
240 |
360 |
600 |
Fans |
Air volume |
m3/h |
1000 |
1200 |
1400 |
1800 |
3000 |
4500 |
6000 |
7000 |
8000 |
Wind pressure |
mm H2O |
375 |
375 |
480 |
480 |
950 |
950 |
950 |
950 |
950 |
Wind pressure |
kw |
3 |
4 |
5.5 |
7.5 |
11 |
18.5 |
22 |
30 |
45 |
Steam consumption |
kg/h |
15 |
23 |
42 |
70 |
141 |
211 |
282 |
366 |
451 |
Compressed air consumption |
m3/min |
0.6 |
0.6 |
0.6 |
0.9 |
0.9 |
0.9 |
1.1 |
1.5 |
1.5 |
Host weight |
kg |
250 |
300 |
700 |
900 |
1100 |
1300 |
1500 |
1800 |
2000 |
Vapor pressure |
MPa |
0.3-0.6 |
Temperature |
℃ |
Temperature range of -120 ℃ adjustable |
Operating time |
min |
With the material characteristics of the 45-90 |
Material yield |
% |
≥99 |
Noise |
dB(A) |
Installation of fan and host isolation, noise ≤ 75dB (A) |
Host size |
m |
1.0×0.55 ×1.8 |
1.2×0.6 ×2.1 |
1.25×0.75 ×2.1 |
1.6×0.9 ×2.3 |
1.85×1.25 ×3 |
2.2×1.65 ×3.3 |
2.34×1.7 ×3.8 |
2.8×1.9 ×3.8 |
3×2.25 ×4.2 | Equipment picture
|
|